service · Q261
Covidence
Hosted literature-review platform for screening, full-text review, extraction and review-flow reporting.
Overview
Covidence is a web-based platform for managing literature reviews from reference screening through data extraction. It records reviewer decisions, supports single or dual screening and provides full-text exclusion reasons and reporting. Its structured extraction workflows and export formats matter when replacing a simpler screening tool or moving an established review.[1][5]
Importing and deduplicating records
The September 2026 import guide lists EndNote XML, PubMed text and RIS. Individual files may contain up to 15,000 references and be up to 50 MB, with one import processed at a time. Larger collections can be divided across imports. These detailed instructions are more specific than generic marketing statements about compatibility with reference managers.[3]
Duplicates are not multiple study reports
Covidence checks each import against itself and earlier imports, keeping the first occurrence as the primary reference. Suspected duplicates remain reviewable and can be returned to the review. Deduplication is distinct from merging separate publications that report the same underlying study, so a team should not use those operations as equivalent cleanup steps.[4]
Choosing an extraction structure
Extraction 1 organizes data around defined groups and outcomes, with structured routes to RevMan and spreadsheet exports. Extraction 2 supports more freely designed fields and tables for narrative or mapping work. Both support single or dual extraction. Switching the selected tool retains the original data, but the documentation explicitly says that data cannot transfer between the two tools.[5]
Automation and inconsistent guidance
The August 27 privacy guide says extraction suggestions are enabled by default when a DOI is available, using external metadata and LLM processing of full texts. It includes both extraction modes, while the August 16 comparison lists automatic suggestions only for Extraction 1. That discrepancy remains unresolved here. The vendor states that its LLMs do not train on or retain supplied PDF data; this is a vendor assurance rather than an independent audit.[5][6]
Review-flow reporting
The PRISMA flow diagram follows imports and review stages, incorporating duplicate counts and full-text exclusion reasons. Merging publications affects study counts differently from reference counts. Its editable DOCX export assumes that studies reviewed in full text were sought for retrieval and initially sets the not-retrieved count to zero. That field needs correction where the actual review differs.[7]
Subscription scope
Individual offerings cover one review or a three-review package for twelve months and allow unlimited collaborators. Institutional subscriptions have different organization-wide entitlements. A trial allows 500 records. Those access arrangements are separate from the technical per-file import limits; the trial should not be read as establishing unrestricted free use for a completed review.[2]
Where it substitutes
Covidence can substitute for Rayyan for collaborative screening and recording exclusion decisions, with its own extraction and reporting environment. Bibliographic imports alone do not recreate another platform’s reviewer history, permissions or forms. The extraction mode and intended analysis exports should be chosen deliberately rather than assuming that all review-management products hold equivalent project structures.[1][5][8]
Capabilities & limitations
Single and dual screening
supportedRecords decisions and full-text exclusion reasons.[1]
Coordinate literature-review screening and extraction · Web · Subscription, institution and extraction-mode requirements apply
1 source · check evidence
Screening, full-text review, extraction, assessment and export
vendor · checked 2026-10-07Reference import
limitedThe current guide lists EndNote XML, PubMed text and RIS; files are capped at 15,000 records and 50 MB.[3]
Coordinate literature-review screening and extraction · Web · Subscription, institution and extraction-mode requirements apply
1 source · check evidence
September 2026 supported formats; 15,000-reference and 50 MB per-file limits
vendor · checked 2026-10-07Extraction-mode migration
unsupportedSwitching modes preserves each mode’s data but does not transfer it to the other tool.[5]
Coordinate literature-review screening and extraction · Web · Subscription, institution and extraction-mode requirements apply
1 source · check evidence
August 16 comparison: data structure, export modes and no transfer between tools
vendor · checked 2026-10-07Extraction 2 automation documentation
disputedThe August 16 comparison excludes automated suggestions; the later August 27 privacy guide includes them.[5][6]
Coordinate literature-review screening and extraction · Web · Subscription, institution and extraction-mode requirements apply
2 sources · check evidence
August 16 comparison: data structure, export modes and no transfer between tools
vendor · checked 2026-10-07August 27: automatic suggestions in DE1 and DE2; DOI and model-data statements
vendor · checked 2026-10-07Can substitute for
These are products or services this entry can replace. Check the task and limitations for each comparison.
Rayyan for Coordinate literature-review screening and extraction
limitedCan cover collaborative reference and full-text screening, adding its own extraction workflow; project state and custom forms are not proven interchangeable.[1][5][8]
Web · Subscription, institution and extraction-mode requirements apply
References
- Covidence reviewer workflow
Screening, full-text review, extraction, assessment and export
vendor · retrieved 2026-10-07 - Covidence subscriptions
12-month review packages, institutional access and 500-record trial
vendor · retrieved 2026-10-07 - Import references into Covidence
September 2026 supported formats; 15,000-reference and 50 MB per-file limits
vendor · retrieved 2026-10-07 - Covidence duplicate management
Automatic and manual duplicates; restoration; distinction from study merging
vendor · retrieved 2026-10-07 - Choosing Extraction 1 or Extraction 2
August 16 comparison: data structure, export modes and no transfer between tools
vendor · retrieved 2026-10-07 - Covidence PDFs and LLM usage
August 27: automatic suggestions in DE1 and DE2; DOI and model-data statements
vendor · retrieved 2026-10-07 - Covidence PRISMA export
DOCX export, study versus reference counts and not-retrieved default
vendor · retrieved 2026-10-07 - Rayyan Blind Mode
Independent screening and disagreement review
vendor · retrieved 2026-10-07
Discussion & disputes
Ask about unclear claims or explain a concern with supporting sources. If you have a specific fix, suggest a correction.
No discussion yet.
Revision history
Open a revision to read an earlier version of this article.
| Revision | Timestamp | Edit summary |
|---|---|---|
| 246 | 2026-10-10 16:29:25 | /* wbeditentity-create-item:0| */ sf:018ec065-c5e3-43dc-9589-58a175c7e0ea:v1 | Add Covidence with current import limits, deduplication versus study merging, non-transferable extraction modes and PRISMA export caveats; qualify inconsistent | attribution: /proposals/018ec065-c5e3-43dc-9589-58a175c7e0ea |