{"schemaVersion":"1.0","record":{"label":"Saleae Logic 2","description":"Saleae's signal capture and protocol-analysis application with native recording and export workflows.","aliases":["Logic 2"],"kind":"software","website":"https://www.saleae.com/support/logic-software","overview":"Saleae Logic 2 is the vendor's desktop application for capturing and analyzing signals with its logic-analyzer hardware. It combines waveform inspection, protocol analyzers and export tools. Saved captures can also be reviewed without owning the acquisition device, while demo mode generates simulated data rather than measuring a physical circuit.","license":"Free download; software cost bundled with Saleae hardware","lifecycle":"active","example":false,"features":[{"name":"Saved capture viewing without hardware","status":"supported","detail":"Saved captures can be opened without owning a Saleae device.","useCase":"Waveform inspection and signal analysis","platforms":["Windows","macOS","Linux"],"region":"Build, file format and acquisition-hardware requirements apply","evidence":[{"url":"https://www.saleae.com/support/ordering-returns/is-the-saleae-software-sold-separately","locator":"Software bundled with hardware; saved capture viewing without hardware","retrievedAt":"2026-10-07T03:46:57Z","kind":"vendor"}]},{"name":"External CSV import","status":"unsupported","detail":"Vendor documentation explicitly excludes external data and reimporting exported CSV.","useCase":"Waveform inspection and signal analysis","platforms":["Windows","macOS","Linux"],"region":"Build, file format and acquisition-hardware requirements apply","evidence":[{"url":"https://www.saleae.com/support/logic-software/saving-and-exporting-data/is-it-possible-to-import-data-into-the-logic-software","locator":"Cannot import external data or reimport exported CSV; alternative viewers identified","retrievedAt":"2026-10-07T03:45:59Z","kind":"vendor"}]},{"name":"Legacy logicdata import","status":"unsupported","detail":"Logic 1.x files require the older application.","useCase":"Waveform inspection and signal analysis","platforms":["Windows","macOS","Linux"],"region":"Build, file format and acquisition-hardware requirements apply","evidence":[{"url":"https://www.saleae.com/support/logic-software/saving-and-exporting-data/saving-loading-and-exporting-data","locator":"SAL capture files, presets and unsupported legacy logicdata import","retrievedAt":"2026-10-07T03:45:59Z","kind":"vendor"}]}],"alternatives":[],"slug":"saleae-logic-2","draftAlternatives":[{"targetSlug":"pulseview","status":"limited","detail":"Alternative vendor workflow for supported Saleae equipment; arbitrary hardware and external trace imports are outside the established scope.","useCase":"Saleae-device capture and native capture inspection","platforms":["Windows","macOS","Linux"],"region":"Build, file format and acquisition-hardware requirements apply","evidence":[{"url":"https://www.saleae.com/support/ordering-returns/is-the-saleae-software-sold-separately","locator":"Software bundled with hardware; saved capture viewing without hardware","retrievedAt":"2026-10-07T03:46:57Z","kind":"vendor"},{"url":"https://www.saleae.com/support/logic-software/saving-and-exporting-data/is-it-possible-to-import-data-into-the-logic-software","locator":"Cannot import external data or reimport exported CSV; alternative viewers identified","retrievedAt":"2026-10-07T03:45:59Z","kind":"vendor"},{"url":"https://sigrok.org/wiki/PulseView","locator":"Qt frontend role and GPL version 3 or later","retrievedAt":"2026-10-07T03:45:43Z","kind":"vendor"}]}],"evidence":[{"url":"https://www.saleae.com/support/logic-software","locator":"Capture, viewing, protocol analyzers and export documentation index","retrievedAt":"2026-10-07T03:45:48Z","kind":"vendor"},{"url":"https://www.saleae.com/support/ordering-returns/is-the-saleae-software-sold-separately","locator":"Software bundled with hardware; saved capture viewing without hardware","retrievedAt":"2026-10-07T03:46:57Z","kind":"vendor"},{"url":"https://www.saleae.com/support/logic-software/capturing-data/demo-mode","locator":"Generated simulation data when no device connected","retrievedAt":"2026-10-07T03:46:15Z","kind":"vendor"}],"document":{"version":1,"references":[{"url":"https://www.saleae.com/support/logic-software/download-and-installation/sw-installation","locator":"Free download and installation on multiple machines; no setup performed","retrievedAt":"2026-10-07T03:46:57Z","id":"saleae-free","title":"Saleae software installation","kind":"vendor"},{"url":"https://www.saleae.com/support/ordering-returns/is-the-saleae-software-sold-separately","locator":"Software bundled with hardware; saved capture viewing without hardware","retrievedAt":"2026-10-07T03:46:57Z","id":"saleae-bundle","title":"Saleae software business model","kind":"vendor"},{"url":"https://www.saleae.com/support/logic-software","locator":"Capture, viewing, protocol analyzers and export documentation index","retrievedAt":"2026-10-07T03:45:48Z","id":"saleae-guide","title":"Saleae Logic software guide","kind":"vendor"},{"url":"https://www.saleae.com/support/logic-software/capturing-data/demo-mode","locator":"Generated simulation data when no device connected","retrievedAt":"2026-10-07T03:46:15Z","id":"saleae-demo","title":"Saleae demo mode","kind":"vendor"},{"url":"https://www.saleae.com/support/logic-software/saving-and-exporting-data/saving-loading-and-exporting-data","locator":"SAL capture files, presets and unsupported legacy logicdata import","retrievedAt":"2026-10-07T03:45:59Z","id":"saleae-save","title":"Saleae capture and preset management","kind":"vendor"},{"url":"https://www.saleae.com/support/logic-software/saving-and-exporting-data/exporting-data","locator":"Raw data, analyzer table, transition-based digital export and final sample","retrievedAt":"2026-10-07T03:46:40Z","id":"saleae-export","title":"Saleae export workflows","kind":"vendor"},{"url":"https://www.saleae.com/support/logic-software/saving-and-exporting-data/is-it-possible-to-import-data-into-the-logic-software","locator":"Cannot import external data or reimport exported CSV; alternative viewers identified","retrievedAt":"2026-10-07T03:45:59Z","id":"saleae-import","title":"Saleae external-data import limits","kind":"vendor"},{"url":"https://www.saleae.com/support/logic-software/download-and-installation/supported-operating-systems","locator":"Windows 10/11 x64, macOS 12+ and Ubuntu 20.04+","retrievedAt":"2026-10-07T03:46:33Z","id":"saleae-os","title":"Saleae supported operating systems","kind":"vendor"},{"url":"https://sigrok.org/wiki/PulseView","locator":"Qt frontend role and GPL version 3 or later","retrievedAt":"2026-10-07T03:45:43Z","id":"pv-home","title":"PulseView","kind":"vendor"}],"overviewCitations":["saleae-guide","saleae-bundle","saleae-demo"],"licenseCitations":["saleae-free","saleae-bundle"],"sections":[{"id":"workflow","heading":"Capture and inspection","paragraphs":[{"id":"workflow-detail","content":[{"text":"The software's workflow moves from device and capture settings to waveform navigation, measurements and protocol analysis. The application itself is downloadable without charge, and Saleae describes its cost as included with its hardware products. This separates the cost of viewing a colleague's recording from the equipment needed to acquire new signals. A demo recording is useful for exploring the interface, but it is not evidence from an attached circuit."}],"citations":["saleae-guide","saleae-free","saleae-bundle","saleae-demo"]}]},{"id":"preservation","heading":"Native files and legacy limits","paragraphs":[{"id":"preservation-detail","content":[{"text":"Current captures use the .sal format, while acquisition presets are separately manageable and exportable. The support documentation says older .logicdata recordings require the older Logic 1.x application and cannot be imported into Logic 2. Preserving historical recordings therefore may require retaining access to that earlier software. A current-version upgrade should not be treated as a guarantee that the complete archive remains directly readable."}],"citations":["saleae-save"]}]},{"id":"exports","heading":"Export is not round-trip migration","paragraphs":[{"id":"exports-detail","content":[{"text":"Raw data export can select channels and a time range, while analyzer tables provide interpreted results. Digital raw exports are transition-based rather than one row per sampled point, with an additional final sample entry. Critically, Saleae says external data cannot be imported into Logic, including CSV previously exported from it. Exported tables are consequently analysis deliverables, not substitutes for retaining the native capture when later interactive review is needed."}],"citations":["saleae-export","saleae-import"]}]},{"id":"platforms","heading":"Availability and substitution scope","paragraphs":[{"id":"platforms-detail","content":[{"text":"Current support lists Windows 10 and 11 x64, macOS 12 or newer on Intel or Apple silicon, and Ubuntu 20.04 or newer. Logic 2 can replace "},{"text":"PulseView","targetSlug":"pulseview"},{"text":" for an appropriate Saleae-device workflow or inspection of its own saved captures. It is not established as a general frontend for arbitrary sigrok instruments, and its import restriction makes it unsuitable as a universal waveform-file viewer. Device requirements and archive formats should be checked before switching."}],"citations":["saleae-os","saleae-bundle","saleae-import","pv-home"]}]}]},"id":"Q954","revision":1002,"updatedAt":"2026-10-13T16:44:16Z","sourceUrl":"https://substitutefor.net/entities/Q954?revision=1002"}}